Flow sensors - Consumption measurement for compressed air

SL90E307

SL90E307
List price
1.248,80 €
On demand
sensor flow, Air, Calorimetric, 176x70x300mm, R 1/2 inch, 12-36V DC, 1x NO (NO), 4-20mA, Plug-in connection M12 5pin, Plastic PC, Pressure resistance 16bar, With display, Parameterization, Ethernet
Compare

Flow sensors - Consumption measurement for compressed air

The function of the flow sensor is based on the calorimetric principle. The probe is heated up from the inside a few degrees Celsius in relation to the flow medium, in which it protrudes. When the medium flows, the heat generated in the probe is dissipated through the medium. The temperature within the sensor is measured and compared with the likewise measured medium temperature. From the obtained temperature difference the flow state of each medium can be derived. These sensors are applied in areas such as monitoring of cooling systems, ventilation systems, pump dry running by checking the presence of liquid or gas flows.

Electrical properties

Number of switching outputs
1
Number of switching points
2
Type of switching function
Normally open contact (NO)
Type of analog output
4 - 20mA
Type of electrical connection
Connector M12
Type of interface connection
Plug-in connection M12
Rated switching current
150mA
Setting procedure
Parameterization
Coding of interface connection
X-coded
Short-circuit protection
Yes
No-load current
120mA
Number of pins
5
Switching voltage
48V
Reverse polarity protection
Yes
Measurement principle
calorimetric
Number of pins of interface connection
8
Supported communication interface
Ethernet
Operating voltage (DC)
12 - 36V
Display
LED display

Mechanical properties

Type of process connection
R1/2 inch
Design
Cuboid
Width
300mm
Pressure resistance
16bar
Height
176.4mm
Length
70mm
Medium temperature
-30 - 80°C
Degree of protection (IP)
IP65
Housing material
Plastic PC
Sensing element material
Stainless steel 1.4301
Measuring range flow volume
3.33 - 1,500l/min
Measuring range flow velocity
0.27 - 123m/s

Other properties

Ambient temperature
-20 - 70°C
Suitable media
Gases
Reference medium / object
Air
For pneumatic applications
Yes
Suitable for liquids
No
Integrated measuring section
You can find accessories for SL90E307 in these product groups:

Cable sockets M12-socket M12-connector 5-wire

Cable sockets M12 5-wire shielded

Connection cable M12-connector RJ45-connector 8-pin

Protection cap, teflon M8

Recalibration of inline flow sensors

Classification Class
eClass-7.0 27371815
eClass-7.1 27371815
eClass-8.0 27371815
eClass-9.0 27371815
eClass-9.1 27371815
ETIM-6.0 EC002580
ETIM-7.0 EC002580
Property Value
RoHS‑compliant Yes
Reach-compliant Yes
IPF Product Group 725 compressed air and leakage measurement
packaging dimensions 230 x 95 x 310mm
gross weight 1,056g
Customs tariff number 90268020
WEEE number 40951076
Compare